OPERATION 3.10 STARTING THE ENGINE 3.10.1 STARTING PROCEDURE NOTICE Machines destined for areas with very low ambient tempera- tures are equipped with electronic pre-heating systems. These pre-heating systems have to be activated as soon as the engine has been stopped. REMARK Before starting read the Engine Operation Manual. Observe the instructions for starting the Engine. After repairs on the Diesel Engine or Starter Motor, make sure that the ground cables are correctly connected before starting the Engines. Start the engine from the operator’s seat only. Never attempt to start the engine by shorting across starter ter- minals. This can cause fire, serious injury or death.
Before each start, ensure that all controls are in neutral position. Be sure to sound the signal horn before starting, in order to make your intention clear. NOTICE Before starting the engine and again before starting work, pay attention to the hydraulic oil temperature. Refer to the paragraph "Hydraulic Oil Warm-up" in this section.
Legend for illustration Z 25400 (1) Key operated main switch (2) Acoustic warning signal (3) ETM text display (4) Engine speed selector switch Low idle - High idle (5) Signal horn button (6) Rotary switch - engine start (7) Rotary switch -engine stop (8) Rotary switch - engine start pilot, cold starting aid (9) Strike button - emergency engine sutdown and cut-out of pilot control system (10) Panel with analogue gauges 171 WARNING WARNING