OPERATION 3.16 STOPPING THE ENGINE Never stop the engine from full load except in case of emer- gency. Before shutting down run the engine at idling speed for approximately 5 minutes. This cooling down period prevents heat accumulation and thermal stress, especially in the tur- bochargers. For EMERGENCY SHUTDOWN of the Engine, use STRIKE BUTTON (9). Additional emergency shut-down switches are located on the power house. For more information See "MACHINERY HOUSE" on page 140. Stopping procedure, see illustration Z25484. 1. Park the Shovel at a safe place on level and solid ground. For more information See "PARKING THE SHOVEL" on page 200. 2.
Deposit the working attachment onto the ground, proceed as follows: A - Backhoe Attachment Lower the backhoe attachment fully extended onto the ground in a position as shown on the oil level plate at the hydraulic oil reservoir, see page 169 for more information. B - Bottom Dump Bucket Attachment Lower the bottom dump bucket attachment onto the ground in a position as shown on the oil level plate at the hydraulic oil reservoir, i.e. the stick cylinders are fully retracted and the bucket is fully rolled back so that the bucket back wall contacts the stick.
The positions A or B are necessary to prevent unintentional movement of the working attachment when the pressure in the hydraulic system is relieved and for correct checking pro- cedure of the hydraulic oil level. 3. Move all controls into neutral position. 4. Set toggle switch (4) to low idle speed position. Let the engine idle for about five minutes without load. 5. Turn switches (8) clockwise to stop position. After the engine has come to standstill, relieve the pressure in the hydraulic system. 203 CAUTION CAUTION CAUTION CAUTION