Komatsu — 3.17.1 OPERATION OF THE AUTOMATIC LUBRICATION SYSTEMS

OPERATION 3.17 AUTOMATIC LUBRICATION SYSTEMS 3.17.1 OPERATION OF THE AUTOMATIC LUBRICATION SYSTEMS The shovel is equipped with two automatic lubrication systems: 1. Central Lubrication System (CLS) for lubrication of the attach- ment bearings, the slewing connection bearing and the slew gear bearing. 2. Slew ring gear pinion Lubrication System (SLS) for lubrication of the slew ring teeth. These systems work automatically as soon as the engine is run- ning at high idle speed. The slew ring gear lubrication system is only activated during slewing movement of the superstructure. The ETM System monitors the function of both lubrication sys- tems.

Trouble conditions of the lubrication systems are indicated through fault messages on the ETM display.

Legend for illustration Z 23096 Electrical components of the Central Lubrication System (CLS) located on the X2 switch board in the cab base D3 Pause time relay, factory setting 60 minutes D4 Monitoring time relay, factory setting 3 minutes D39 Time relay for switching off the bucket motion if the lubrication system fails to function over a period longer than 4.2 hours K28 Relay initiates a fault message if power supply to the lubrication system is interrupted K30 Relay initiates a fault message if the lubrication cycle is not carried out in the adjusted time period K136 Relay initiates a fault message if the grease barrel is empty Electrical components of the Slew ring gear Lubrication System (SLS) D7 Pause time relay, factory setting 9 minutes D8 Monitoring time relay, factory setting 2 minutes D40 Time relay for switching off the bucket motion if the lubrication system fails to function over a period longer than 4.2 hours K35 Relay initiates a fault message if power supply to the lubrication system is interrupted K37 Relay activates the slew ring gear lubrication system during slewing of the superstructure K38 Relay initiates a fault message if the lubrication cycle is not carried out in the adjusted time period K138 Relay initiates a fault message if the grease barrel is empty B43 Line pressure switch of CLS interrupts lubrication cycle B46 Line pressure switch of SLS interrupts lubrication cycle S24 Rotary switch for manual actuation of the CLS S26 Rotary switch for manual actuation of the SLS 207