Komatsu — 4.7.3 AUTOMATIC LUBRICATION SYSTEMS FILL GREASE CONTAINERS

MAINTENANCE 4.7 WHEN NECESSARY 4.7.3 AUTOMATIC LUBRICATION SYSTEMS FILL GREASE CONTAINERS Fill the grease containers of the Central Lubrication System and Swing circle pinion Lubrication System when the corresponding message "grease container empty" is displayed on the ETM screen. Make sure the grease filters in the filling lines are not obstructed. If necessary service the Grease Filters. Legend for illustration Z21666A (1) Grease level gauges for manual checking of the grease level (2) Grease filter for central lubrication system. Before filling the grease container make sure the filter is not obstructed. Service the filter element according to the instructions on next page.

(3) Grease container of the central lubrication system (5) Grease filter for swing circle pinion lubrication sys- tem. Before filling the grease container make sure the filter is not obstructed. Service the filter element according to the instructions on next page. (6) Grease container of the swing circle pinion lubrica- tion system Fill the grease containers according to the instructions on page 192. REMARK Check condition and fastening of both grease containers. 275