MAINTENANCE 4.9 EVERY 50 OPERATING HOURS OR WEEKLY 4.9.1 SWING GEAR AND MOTOR ADAPTER HOUSING - CHECK OIL LEVEL REMARK The machine can be equipped either with a swing gear of manufacturer "L&S" or of manufacturer "Siebenhaar". Refer to the data plate on the swing gear housing to find out the manufacturer of the swing gear. Swing gear manufactured by "L&S" Legend for illustration Z22913 Swing gear (A) Position of oil level gauge for checking the oil levels (1) Oil level gauge (2) Oil filler plug (3) Breather filter (7) Drain coupling or evacuation nozzle for Wiggins sys- tem Motor Adapter Housing (4) Oil level gauge and filler opening.
This opening can also be used for connecting a suction pump when changing the oil. (5) Breather filter (6) Oil drain plug CHECK SWING GEAR OIL LEVEL Remove oil level gauge (1), illustration Z22913 and wipe it clean. Insert the gauge but DO NOT screw in, see detail ”A”. Remove the gauge. The oil level should be at the upper mark of gauge (1). If necessary add the specified gear oil through filler opening (2). Remove breather filter (3). Blow out with compressed air from inside to outside and reinstall. CHECK MOTOR ADAPTER HOUSING OIL LEVEL Remove oil level gauge (4) and wipe it clean. Insert the gauge but DO NOT screw in, see detail ”A”. Remove the gauge.
The oil level should be at the upper mark of gauge (4). If necessary add the specified oil through filler opening (4). Remove breather filter (5). Blow out with compressed air from inside to outside and reinstall. 301