Komatsu — 4.10.5 HYDRAULIC OIL COOLER FAN - CHECK CONDITION AND FASTENING

MAINTENANCE 4.10 EVERY 250 OPERATING HOURS OR MONTHLY 4.10.4 SIGNAL HORN COMPRESSOR - LUBRICATE See illustration Z 10689 The compressor (2) is located in the cab base. Fill several drops of thin oil into the lubricator (1). The oil must be free from resin and acid and must have the lowest solidifying-point possible (below - 40° C). NOTICE If the Excavator is equipped with a second signal horn there is also a second compressor which has to be lubricated in the same way as the first one.

4.10.5 HYDRAULIC OIL COOLER FAN - CHECK CONDITION AND FASTENING Legend for illustration Z24058 (1) Oil cooler carrier (2) Cooler fan (3) Mounting bolt (4) Thrust block (5) Mounting bolt (6) Hydraulic motor (7) Mounting bolt Check condition of cooler fan (2). Make sure all bolts (3) are in place and correctly tightened. Check hub mounting bolt (5) for correct tightening torque. Check hydraulic motor (6) for leakage. Make sure all bolts (7) are in place and correctly tightened. Refer to Standard Torque List on page 249 for bolt tightening torques. 323