Komatsu — 4.12.1 HIGH STRENGTH BOLT CONNECTIONS - CHECK TORQUE LOAD

MAINTENANCE 4.12 EVERY 1000 OPERATING HOURS OR EVERY 6 MONTH High-Strength Bolt Connections (continued) Check fastening and condition of control valve carrier (01), main control valves (04 - 06) and hose support (02), illustration Z20861 * SW = Wrench size Reference No.: Qty. (17) 8 (19) 6 (20) 3 (30) 4 Check all mounting bolts (17, 19, 20 and 30) for correct tight- ening torque. Re-tighten loose mounting bolts and replace missing or dam- aged bolts. 355 Bolt size mm Grade SW * mm Tightening torque Nm M12 8.8 19 74 M16 8.8 24 179 M16 8.8 24 179 M20 10.9 30 510