Komatsu — 4.12.1 HIGH STRENGTH BOLT CONNECTIONS - CHECK TORQUE LOAD

MAINTENANCE 4.12 EVERY 1000 OPERATING HOURS OR EVERY 6 MONTH High-Strength Bolt Connections (continued) Center frame (1), check condition and fastening of swivel joint (2), illustration Z24071 * SW = Wrench size Reference No.: Qty. (3) 4 (4) 8 Check all mounting bolts (3 and 4) for correct tightening torque. Re-tighten loose mounting bolts and replace missing or dam- aged bolts. 363 Bolt size mm Grade SW * mm Tightening torque Nm M 16 10.9 24 265 M 16 10.9 24 265