Komatsu — 4.13.1 HYDRAULIC SYSTEM - CHANGE OIL, REPLACE SUCTION STRAINERS AND PULSATION DAMPER

MAINTENANCE 4.13 EVERY 2000 OPERATING HOURS OR YEARLY 4.13.1 HYDRAULIC SYSTEM - CHANGE OIL, REPLACE SUCTION STRAINERS AND PULSATION DAMPER The hydraulic oil change intervals can be extended for a further time period, when an oil sample analysis shows a positive result. When extending the oil change interval, it is necessary to carry out an oil sample analysis after every 1000 operating hours. However, it is recommended to change the hydraulic oil and the suction strainers after 6000 operating hours at the latest. NOTICE The pulsation damper must be replaced after every 2000 operating hours. Legend for illust.

Z25010 (1) Main oil reservoir (2) Hand wheel of main shut-off valve (3) Compensator. Check condition and tightness of compensator and connected parts. (4) Intermediate pipe (5) Suction strainer (6) Suction strainer flange (7) Gaskets (8) Suction oil reservoir Sequence of Servicing Evacuate main hydraulic oil reservoir. Proceed according to section "Central Refilling System" on page 218. Drain the oil from return oil manifold, see page 401 for more information. Drain the oil from suction oil reservoir, see page 403 for more information. Replace main suction strainer (5) with gaskets (7), illustration Z25010. Replace suction strainers of the hydraulic pumps, see page 403 for more information.

Replace oil cooler strainer and pulsation damper, see page 401 for more information. REMARK With hydraulic oil reservoir empty, service the return oil filters and leakage oil filter. Inspect the reservoir for sediments. Clean the reservoir if necessary. 399