MAINTENANCE 4.13 EVERY 2000 OPERATING HOURS OR YEARLY Hydraulic oil viscosity and adjustment of tempera- ture switch units If the new hydraulic oil has a different viscosity grade compared with the drained oil it is necessary to adjust the temperature limit values at switch units (K26, K39 and K100), illustration Z24089 in accordance with the viscosity grade of the new hydraulic oil. The switch units are located in the X2 switch box in the cab base. Legend for illustration Z24089 K26 - Switch unit for hydraulic oil cooler fan speed control. K39 - Switch unit for hydraulic oil temperature warning message “Hydraulic Oil Temperature too high“.
K100 - Switch unit for pre-load of hydraulic oil cooler circuit Adjust switch units to the respective oil viscosity grade as follows: Adjustment procedure for (K26, K39 and K100): Adjust the temperature limit value at the cogwheel next to the drum scale on switch unit front cover. NOTICE Turn the cogwheel sensitively. DO NOT turn beyond the STOP marking, otherwise the internal potentiometer driver pin will disengage resulting in wrong value transmission. Refer to Service Bulletin No. AH02508b for functional test of the switch unit. REMARK The switch unit (K8) is used for engine coolant temperature warning message. DO NOT change the setting of this unit.
The switch units (K43) and (K182) are used for adjustment of the pump distributor gear oil viscosity. 409 Oil viscosity grade according to ISO VG 22 VG 32 VG 46 VG 68 VG 100 SHELL SL0851 -K26- Adjust temperature limit value to switching point °C +32° +41° +50° +58° +67° +39° -K39- Adjust temperature limit value to switching point °C +58° +69° +79° +85° +85° +81° -K100- Adjust temperature limit value to switching point °C +9°C +16°C +25°C +32°C +39°C +39°C