MAINTENANCE 4.14 EVERY 3000 OPERATING HOURS HOWEVER AT LEAST ONCE A YEAR 4.14.3 PTO (PUMP DISTRIBUTOR GEAR) - CHANGE OIL Legend for illustration Z24055 (1) Oil level gauge (2) Oil filler plug (3) Breather filter (4) Oil drain plug (5) Adapter housings for main hydraulic pumps (6) Adapter housing for pilot oil pump (7) Oil level plug (8) Oil filler plug with breather pipe (9) Oil drain plug Gear Oil Viscosity Select gear oil viscosity grade according to ambient tempera- tures. If the new gear oil has a different viscosity grade compared with the drained oil it is necessary to adjust the temperature switch units according to the table on page 429.
REMARK Before opening the access covers from below the pump dis- tributor gear provide an adequate working platform with sufficient space for the oil collecting container (approx. 100 liters). Change the Oil 1. Remove drain plug (4), gauge (1) and filler plug (2). 2. Remove breather filter (3), blow out with compressed air from inside to outside and re-install. 3. After the oil is completely drained, flush the gear with the reg- ular gear oil and reinstall drain plug (4). 4. Fill in new oil through opening (2) up to the “MAX” mark on gauge (1). 5. Re-install parts (1 and 2). 6. Vent the PTO lubrication pump, see page 411 for more infor- mation. 7.
After short operating period, check oil level and housing for leakage. REMARK If the oil level is above the "MAX" mark, drain the oil down until the oil level is at the "MAX" mark. Too much oil in the pump distributor gear will cause aeration of the oil. 427