MAINTENANCE 4.14 EVERY 3000 OPERATING HOURS HOWEVER AT LEAST ONCE A YEAR PTO gear oil viscosity and adjustment of tempera- ture switch units If the new gear oil has a different viscosity grade compared with the drained oil it is necessary to adjust the temperature limit val- ues at switch units (K43 and K182), illustration Z24089 in accor- dance with the viscosity grade of the new gear oil. The switch units are located in the X2 switch box in the cab base. Legend for illustration Z24089 K43 - Switch unit for gear oil temperature warning message "PTO oil Temperature too high“.
K182 - Switch unit for pre-load of gear oil cooler circuit Adjust switch units to the respective oil viscosity grade as follows: Adjustment procedure for (K43 and K182): Adjust the temperature limit value at the cogwheel next to the drum scale on switch unit front cover. NOTICE Turn the cogwheel sensitively. DO NOT turn beyond the STOP marking, otherwise the internal potentiometer driver pin will disengage resulting in wrong value transmission. Refer to Service Bulletin No. AH02508b for functional test of the switch unit.
429 Oil viscosity grade according to ISO HLP T32 CLP 150 SAE 75W-90 -K43- Adjust temperature limit value to switching point °C +60° +95° +95° -K182- Adjust temperature limit value to switching point °C +48° +15° +54°