OPERATION 3.4 ELECTRONIC TEXT MONITORING SYSTEM ETM 3.4.2 SYSTEM COMPONENTS see illust. Z 23090 (A) Text Display Unit Plaintext messages Multi-lingual text display Text store for all available texts Record memory capacity for max. 1300 mes- sages Statistics memory for frequency and total time period of the messages (B) Key board with 8 keys Function of the keys, refer to page 91 (G) Acoustic warning signal Indicates fault messages (F) Connector for printer Special equipment Switches for the adjustments of the ETM system (C) “Service” key switch for deletion of Record - and Statis- tics memory contents The erasure function is stored under message no. 30.
(D) Pre-selector switch for the following settings: “0” - Off “1” - Setting of Date “2” - Setting of Time of day “3” - Setting of Operating Hours (E) Key switch, enables the settings selected with switch (D). The adjustments are stored under message nos. 27, 28 and 29. NOTICE Settings with key switches (C and E) must only be done by authorized Service Personnel. Refer to page 113 for setting procedure. 93