Komatsu — 3.4.3 FUNCTIONS OF THE ETM SYSTEM

OPERATION 3.4 ELECTRONIC TEXT MONITORING SYSTEM ETM NOTICE The steps for operating the ETM keyboard are indicated by the key symbols. Call up the Basic Display from any message If a fault condition occurs (e.g. message 21) it is possible to call up the basic display for information of current time or engine speed. Example: Message 21 $h: 5200:27 Central lubrication system: grease barrel empty The grease consumption can be determined, when the operating hours at the time of the last refilling or replacement of the grease barrel have been recorded.

PAGE NO Page 21 displayed 4 Press, until page 0 appears 2 UP Press, to display message 0 (basic display) 1 MESSAGE On the screen appears the basic display, e.g.: 15.07.07 14 : 36: 39 h: 5200:27 1/min: 1800 Message 0 will only be displayed for a few seconds, then the dis- play returns to the current message. 97