MAINTENANCE PLAN 4.7.1 WHEN REQUIRED 4.7.1.a CHECKING, CLEANING OR CHANGING THE AIR CLEANER CARTRIDGE DANGER Remove the air cleaner only after stopping the engine and do not start the engine if the air cleaner is open. Always wear goggles while cleaning the filter. 145 IMPORTANT 00 00000 H F C E A • The air filtering system comprises a primary filtering ele- ment with great capacity and a secondary cartridge that provides additional safety protection. The primary element can be cleaned with compressed air, while the safety cartridge can only be changed.
• The filtering element must be cleaned when the clogging warning light (A) positioned on the instrument panel blinks or comes on completely. In any case, check the cartridge for any clogging every 50 hours of operation of the machine. 00 00000 H F C E A The air cleaner can be reached after opening the engine hood (see “3.5.1 ENGINE HOOD”). To clean the primary element, proceed as follows: 1 - Pull the yellow safety device (1) to release the cover. 2 - Rotate the filter cover (2) anticlockwise and remove it. 3 - Extract the main filtering element (3).
4 - Slightly strike the element on the palm of your hand to elimi- nate the dust and blow compressed air on the inner surface, keeping the air jet at a distance of approximately 15 cm and making sure that the pressure does not exceed 4-5 bars. 5 - Carefully clean the inside of the filter casing (4), taking care to avoid the introduction of foreign matters in the suction duct. 6 - Reassemble the filtering element (3), making sure that it is correctly positioned in its seat. RYA15820