Komatsu — 4.7.13.c CHANGING THE HYDRAULIC SYSTEM OIL AND CLEANING THE SUCTION FILTER

MAINTENANCE PLAN 181 4.7.13.c CHANGING THE HYDRAULIC SYSTEM OIL AND CLEANING THE SUCTION FILTER CAUTION • On machines containing synthetic biodegradable hydraulic oil type HEES, carry out the change after the first 500 hours of operation and successively every 2000 hours, and in any case at least once a year. CAUTION • On machines containing synthetic biodegradable hydraulic oil type HEES, carry out the change after the first 500 hours of operation and successively every 2000 hours, and in any case at least once a year.

RYA15890 RYA15900 RYA15890 DANGER • Retract the bucket and arm cylinder completely, extend the cylinders of the two-piece boom completely, lower the bucket teeth to the ground and, after stopping the engine, release the residual pressures from the work equipment circuits (by operating the controls more than once) and from the tank (by slowly loosening the filling cap). • Let the oil cool down until it reaches 40-45°C before carry- ing out any maintenance operation. • Immediately clean any area dirty with oil. • Oils, filters, coolants and batteries are considered special waste and must be collected and disposed of according to the anti-pollution regulations in force.

1 - Rotate the upper structure by 90°, in such a way as to leave the lower part of the hydraulic oil tank free from the tracks. 2 - Retract the bucket and arm cylinder completely, extend the cyl- inders of the two-piece boom completely, lower the boom until the bucket teeth touch the ground. 3 - Lower the blade to the ground. 4 - Stop the engine and release the residual pressures from the equipment circuits by shifting the controls more than once. 5 - Open the right side cover (see “3.5.2 SIDE COVER”) and slowly loosen the filling cap (1) to release the residual pres- sure.