Komatsu — 4.7.13.d CHANGING THE COOLANT

MAINTENANCE PLAN 4.7.13.d CHANGING THE COOLANT DANGER 184 • Soon after the machine has been stopped the coolant is very hot and under pressure and it may cause serious burns; let the engine cool down until it reaches approxi- mately 40-45°C before changing the coolant. • Slowly loosen the radiator cap, in order to release the re- sidual pressure. • Oils, filters, coolants and batteries are considered special waste and must be collected and disposed of according to the anti-pollution regulations in force.  IMPORTANT • The change of the permanent coolant does not require the descaling of the circuit. 1 - Open the engine hood (See “3.5.1 ENGINE HOOD”).

2 - Loosen and remove the upper cap (1) of the radiator. 3 - Loosen and remove the drain plug (2) of the radiator, loosen the drain valve (3) positioned on the engine block and let the fluid flow out. Use 6 and 12 mm hexagon spanners. While the fluid flows out, drain the coolant tank (4). 4 - Put back the drain plug (2), close the valve (3) on the engine block and fill the radiator with new fluid (see “4.3 FUEL, COOL- ANT AND LUBRICANTS”). 5 - Start the engine and let it idle for a few minutes; check the lev- el again and if necessary top up before putting back the upper cap (1). 6 - Fill the tank (4) until reaching the maximum level. 7 - Close the engine hood.