hitachi — PUMP CONTROL

SYSTEM / Control System Pump 1 Flow Rate Limit Control (Only Machine Equipped with Front Attachment) Purpose: Limits pump 1 flow rate in order to make up for pump flow rate for front attachment operation when a front attachment (mainly a vibrating hammer) is used and pump 2 flow rate is lack. Operation: 1. When a front attachment is used with the travel control lever in neutral, MC receives the signals from pressure sensor (auxiliary) (optional). 2. In response to front attachment control operation, MC drives the maximum pump 1 flow rate limit control solenoid valve (optional) and controls pump 1 flow rate. NOTE:

The minimum pump swash set-angle on monitor unit for a front attachment (hydraulic breaker 1 to 5, secondary crusher 1 to 5, hydraulic crusher 1 to 5 or vibrating hammer 1 to 5) can be set in the service mode of Dr. ZX. T2-2-34