COMPONENT OPERATION / Pump Device OUTLINE The pump device consists of transmission (6), main pumps (1, 3) and pilot pump (2). The engine output is transmitted to transmission (6) via coupling (8). After being distributed by the gear, the engine power drives main pumps (1, 3) and pilot pump (2). Both reduction gear ratios of engine and main pumps (1, 3) are 1:1.108, engine and pilot pump (2) is 1:1. Main pumps (1, 3) are bent-axis type variable displacement axial plunger pumps. Pilot pump (2) is a gear pump. Pump delivery pressure sensors (4, 5) are installed in order to control the pump and valve.
(Refer to the Control System / SYSTEM.) 6 2 1 7 T1V7-03-01-001 5 4 1 - Main Pump 1 3 - Main Pump 2 5 - Pump 2 Delivery Pressure Sensor 7 - Coupling 2 - Pilot Pump 4 - Pump 1 Delivery Pressure Sensor 6 - Transmission T3-1-1 3