hitachi — ENGINE CONTROL

SYSTEM / Control System E Mode Control Purpose: Reduces the engine speed set by the engine control dial according to the pump control pressure and the average pump delivery pressure in order to reduce fuel consumption and noise level. Operation: 1. When the required engine speed by the engine control dial is 1800 min -1 or faster and the power mode switch is in the E mode position, and if the pump control pressure and the average pump delivery pressure are within the following conditions, MC sends the signals equivalent to the target engine speed to ECM by using CAN communication. 2. ECM reduces the engine speed from the required engine speed set by the engine control dial. 3.

If the pump control pressure is high and the average pump delivery pressure is low, MC sends the signal equivalent to the target engine speed to ECM by using CAN communication. 4. ECM increases the engine speed by 200 min -1 . Condition: Pump Control Pressure: Low (Reference: 3 MPa (31 kgf/cm 2 , 436 psi) or less) or Average Pump Delivery Pressure: High (Reference: 17 MPa (173 kgf/cm 2 , 2471 psi)) Engine Speed Operation Steps 1, 2 Engine speed increase by 200 min -1 . Operation Steps 3, 4 Engine Control Dial Position Slow Idle Fast Idle T2-2-12