. MAINTENANCE SERVICE PROCEDURE CHECK AIR CONDITIONER CHECK LEVEL OF REFRIGERANT (GAS) WARNING 4 - 34 If the refri gerant used in the air c onditioner gets into your eyes or on your hands, it may cause loss of sight or frostbite. Do not touch the refrigerant. Never loo sen any part of the refr Do not br leaking. 1. Start 2. Pres powe 3. Pres 4. Pres moni 5. Open 6. Pres switc 7. Use chec in the the engine and set th e engine speed to appr ox. 1500 rpm. s main power switch (1) of the air conditioner to turn the r ON. s fan switch (2) and set the air flow to "Hi". s temperature control switch (3) and set the display tor to COOL (A). the door and window fully.
s air conditioner switch (4) to turn the air conditioner h ON. sight glass (6) (inspe ction window) of receiv er drier (5) to k the condition of the refrigerant gas (freon 134a) flowing refrigerant circuit. ity of refrigerant tion of sight glass er switch is turned ON, few bubbles A: Quant B: Condi a: Prope r: After air condition are se pale m en and refrigerant be comes milk-white and t hen becomes ilk-white. b: Insuffi cient refrigerant: Afte r air conditioner switch is turned ON, bubble s are seen continuo usly. X: Condi tion of refrigerant flo w d liquid of refrigerant are mixed. Y: Condi tion of sight glass x: There are bubbles: Gas an d liquid of refrigerant a y: There are not bubbles:
All refrigerant is liquefied and arent. transp z: Refrig erant is milk-white: O il and refrigerant are s eparated from each o ther and their mixtur e is pale milk-white.