47 REGULAR CHECKS AND MAINTENANCE WORK EVERY 1000 SERVICE HOURS OR ONCE A YEAR B Replacing Air Filter Element Open the engine hood and remove the dust- cover. Remove and replace the outer element and inner element with new elements. When reassembling, install the dust-cover so that its TOP mark (arrow) faces up-wards. B Hydraulic Oil Check with Hydraulic Breakers The hydraulic oil change after 1000 operating hours in the operator's manual is based on the type of work done. The following inspection measures are valid when hydraulic breakers are used: 1.
Changing and filling up of hydraulic oil (1) The hydraulic oil must be changed more often when breakers are used because the machine is subject to harder conditions than at normal excavating work. (2) Use only the recommended oils mentioned in the operator's manual when changing or topping up oil. (3) When filling up oil, do not mix oils of different makes. 2. Changing the return filter and oil (1) The filter must be changed more often because of contamination resulting from the frequent assembly and disassembly of the hoses. (2) Use the correct replacement filter. (3) Oil change according to operating hours.
(1) Outer element (2) Inner element (3) Case (4) Dust-cover (5) Clamps A Shorten the replacement period if using in lots of dust or sandy areas. EVERY 1500 SERVICE HOURS B Checking Fuel Injection Nozzle (Injection Pressure) Consult your local KUBOTA Dealer for this service. EVERY 2000 SERVICE HOURS Do all 50, 200, 500 and 1000 hour servicing at the same time. B Changing Front Idler and Track Roller Oil A Contact your KUBOTA dealer for details. B Checking the Dynamo and Starter Motor A Contact your KUBOTA dealer for details. Hydraulic oil volumes Hydraulic tank approx. 12.4 L Whole oil volumes approx. 14.4 L Hydraulic oil Return Filter Suction Filter Normal excavator work every 1000 Hrs.
1000 Hrs. Breaker work Portion 20% every 800 Hrs. 40% every 600 Hrs. 60% every 400 Hrs. more every 200 Hrs.