Kubota — Cleaning the Track Frame Telescopic Beams

49 REGULAR CHECKS AND MAINTENANCE WORK OTHER SERVICING A Do not operate the engine without coolant. A To fill the radiator system use fresh water and anti-freeze fluid. A When the anti-freeze is mixed with water, the ratio must not exceed 50%. (a 50/50 mix is recommended) A Tighten the radiator cap properly. If the cap is loosely or not properly fitted, overheating of the engine can result due to coolant fluid loss. B Cleaning the Track Frame Telescopic Beams When the track frame telescopic beams are clogged or covered with soil or sand, clean the slide pipes as follows according to need. To avoid the personal injury or death:

A Place the machine on even ground when cleaning the track frame telescopic beams. B Replacing Fuel Hose Replace the hoses and clamps. (See "Checking Fuel and Intake Air Line" every 2000 hours maintenance.) 1. First lift the machine off the ground using the dozer blade and boom functions. 2. Switch the track width change / dozer select lever to the "Track width change" position. 3. Pull the control lever backward, and expand the track width to 860mm. 4. Remove soil and sand adhered to the telescopic beams, then put grease evenly around the pipes. Make sure all 4 telescopic beams are greased. 5.

Retract and expand the track width repeatedly a few times by moving the control lever, so that the grease is spread adequately. 6. Switch the track width change / dozer select lever to the "Dozer" position. 7. Place the machine down on the ground carefully by moving the dozer blade and the boom. B Replacing Intake Air Line Replace the hoses and clamps, if necessary. (See "Checking Fuel and Intake Air Line" every 2000 hours maintenance.) (1) Track frame telescopic beams