ce t — Pump Control, All Models

ELECTRICAL ELECTRIC/HYDRAULIC Pump Control, All Models 1) In S,H and Auto modes supply current to Electro-magnetic proportional solenoid valve on the side of the pump, will control the HP requirement of hydraulic pumps P1 and P2. Note: The controller needs a RPM signal for proportional solenoid pump control. H -MODE: when pump torque amounts to 100% of engine target torque a variable electrical signal is sent to the proportional solenoid. It varies with engine RPM. S -MODE: when pump torque amounts to 95% of engine target torque a constant electrical signal is sent to the proportional solenoid. L -MODE:

when pump torque amounts to 70% of engine target torque no electrical signal is sent to the proportional solenoid. AUTO -MODE: when pump torque varies between 90% to 93% of engine target torque. An electrical signal is sent to the proportional solenoid based on the mode. The mode switches between S A mode to L A mode depending on conditions. The current will equal S mode + 40mA for S A to S mode for L A mode. When operating in auto-mode and S A mode is active and the travel pressure switch is activated (closed) the machine will stay in S A mode until the travel switch opens.

If the machine is in L A mode when the travel pressure switch closes the machine will stay in L A mode until the travel pressure switch opens. When operating in L mode and the travel pressure switch closes the machine will operate with the mA current of S mode. If the hammer pressure switch closes the machine will operate with the mA current of S mode. Engine revolutions must exceed approximately 1500 rpm’s before the controller sends current to the pump proportional solenoid. 4 - 24 CX EXCAVATORS