ce t — Swing Brake, All Models

ELECTRICAL ELECTRIC/HYDRAULIC Swing Brake, All Models 1) The mechanical swing brake will apply 5 seconds after the swing hand control is returned to neutral. 2) The brake solenoid valve is turned on when the key switch is turned on. When the swing and an attachment function are operated simultaneously, the mechanical swing brake is automatically released. When the operation stops, the mechanical swing brake is automatically activated by the main controller. The swing brake is automatically deactivated when: - The swing pilot pressure switch is activated. - When the pressure at the pressure detectors P1 or P2 is higher than 2075 psi. The swing brake is automatically activated when:

- The pilot pressure switch (6) is deactivated for more than 5 seconds. - The starter switch (3) is in the OFF position. 4 - 34 CX EXCAVATORS