HYDRAULICS – CX130/CX160 FEATURES Cushion Operation (OFF) (Boom and Arm) 1) When pilot oil from the cushion solenoid is sent to the cushion valve, the orifices are shifted out of the circuit and the cushion feature will not function. Note: The Controller needs a RPM signal for Cushion Off. During cushion off operation, the dirt release from the attachments is improved by the sudden stopping (shock) of the arm and boom operations. When the cushion off button is pressed, a signal is sent to the controller. The controller sends a 24v signal to the cushion solenoid valve, the valve is shifted and pilot pressure is directed to the S port of the cushion valve.
The pressure that enters the S port shifts the four-metered valve spools in the cushion valve to allow free flow of the arm and boom control signals through the valve. This allows the arm and boom control valves to return to neutral immediately when the control levers are returned too neutral. The cushion off solenoid is located in the six-solenoid valve bank. Cushion OFF Solenoid Pilot Pressure Solenoid Blue Wire Band Light Green Wire Band 5 - 36 CX EXCAVATORS