HYDRAULICS – CX130/CX160 FEATURES Main Relief Valve The Main Relief has two adjustments: Standard Main Relief pressure Power Boost Pressure When pilot signal port is pressurized, power boost piston shifts to the position shown. Thus the pilot spring force rises, and pressure increases (POWER BOOST). 1. In H or S mode, when the one-touch power boost switch is pressed, power boost operation is executed for 8 seconds. 2. In L mode power boost is on full time. 5 - 40 CX EXCAVATORS