HYDRAULICS – CX210/CX240 FEATURES Free Swing Operation 1) An orifice leak is opened between the A and B ports of the swing motor. This will provide smoother starts and stops of the swing during hoisting operations. Note: The controller needs an input signal from the engine controller for free swing. The free swing operation dampens the oil pressure and flow surges to the swing motor during starting and stopping. This provides for smoother starts and stops during swing operations. When the free swing switch is ON , the controller sends a 24v signal to the free swing solenoid valve.
The valve is shifted and allows oil to free flow, through an orifice, between both main ports of the swing motor. The valve creates a restricted by-pass of the swing motor when starting swing operations and a by-pass of the swing motor when stopping. When free swing is ON , the swing brake is released and does not come on. The free swing solenoid valve is located behind the cab. Free Swing Solenoid Valve Back of cab 6 - 44 CX EXCAVATORS