ce t — AIR HEATER

CX210/CX240 ELECTRONIC FUEL SYSTEM AIR HEATER An air heater at the inlet of the intake manifold, assists in cold starting of the engine and the reduction of white smoke during warm-up. The air heater is a solenoid operated integrated grid device, installed at the entrance to the intake manifold and is controlled by the ECM. The ECM determines when to actuate the air heater based on intake air temperature and fuel temperature. If the intake air temperature sensor fails, the fuel temperature sensor will be used. An Engine Pre Heat indicator in the machine monitor indicates the air heater is energized and preheating. The air heater uses two separate grids to heat the air.

After start up the grids are cycled on and off to reduce white smoke during warm up. The heat cycle is determined by the ECM based on intake air temperature and fuel temperature. If the fuel temperature is lower than intake air temperature, fuel temperature will take priority in controlling the cycle. If the engine does not start, the pre-heat cycle can be restarted by turning the key off and back on. The air heater functions are terminated when the engines load exceeds 10% for more than 10 seconds or when intake air exceeds 66 degrees F. The two grids of the air heater receive current from the battery through two separate Bosch relays. The relays are controlled by the ECM.

8 - 12 CX EXCAVATORS