Komatsu — Locking the Machine

OPERATION Checks After Completion of Operation Before Stopping Engine Use the meters and lamps on the machine monitor to check the engine water temperature, engine oil pressure, torque converter oil temperature, and fuel level. If the engine has overheated, do not stop it suddenly. Run the engine at a mid-range speed to allow the engine time to cool down before stopping it. After Stopping Engine Walk around the machine and check the work equipment, chassis, and undercarriage. Check that there are no loose bodywork mounting bolts. Check that there are no cracks in the work equipment or bucket. Check for oil and water leakage. Fill the fuel tank.

Check the engine compartment for paper and debris. Clean out any paper and debris to avoid a fire hazard. Remove any mud stuck to the undercarriage. Locking the Machine Always lock the following parts. (1) Fuel tank filler cap (2) Engine side panel (four places) (3) Cab door (two places) (4) Engine hood (one place) (air cleaner cover) Remark The starting switch key is used for locks (1), (2), (3), and (4). 2-98 WA500-3LK