OPERATION If Battery is Discharged Precautions It is dangerous to charge a battery when it is mounted on a machine. Make sure that it is removed before charging. When checking or handling the battery, stop the engine and turn the starting switch key to the OFF position. The battery generates hydrogen gas; there is a hazard of explosion. Do not smoke nor bring lighted cigarettes near the battery, or do anything that will cause sparks. Battery electrolyte is dilute sulfuric acid; it will attack your clothes and skin. If it gets in your eyes, wash your eyes out with copious amounts of fresh water and consult a doctor immediately.

If it gets on your clothes or on your skin, immediately wash it off with a large amount of water. When handling batteries, always wear safety glasses and rubber gloves. When removing the battery, first disconnect the cable from the negative (-) terminal. When installing, connect the positive (+) terminal first. If a tool touches the positive terminal and the chassis, there is danger that it will cause a spark. Be extremely careful. If the terminals are loose, there is danger that the defective contact may generate sparks that will cause an explosion. When removing or installing the terminals, check which is the positive (+) terminal and which is the negative (-) terminal.

Remark The batteries are on both sides at the rear of the machine. The battery used for the ground is on the right side of the machine. Removing the Battery 1. Remove the ground cable (normally connected to the negative (-) terminal). Loosen the nuts of the terminal and remove the cable from the battery. If any tool touches between the positive terminal and the chassis, there is danger of sparks being generated. 2. Loosen the nuts and remove the cable from the positive (+) terminal. 3. Remove the battery clamp. 4. Remove the battery. Installing the Battery 1. Install the battery and fix it securely with the battery clamp. Tightening torque:. . . . . . . . . . . .

2.0 to 2.9 N•m (17.7 to 25.7 lbf in) 2. Connect the cable to the positive (+) terminal. Insert the hole of the terminal on the battery and tighten the nuts. Tightening torque:. . . . . . . . . . . . 5.9 to 9.8 N•m (52.2 to 86.7 lbf in) 3. Connect the ground cable to the negative (-) terminal and tighten the nuts. 2-120 WA500-3LK