OPERATION Engine ( ): Always contact your Komatsu distributor when dealing with these items. In cases of abnormalities or causes which are not listed below, contact your Komatsu distributor for repairs. 2-128 WA500-3LK Problem Main Causes Remedy Engine oil pressure caution pilot lamp illuminates. • Engine oil pan level is low (sucking in air). • Clogged oil filter cartridge • Defective tightening of oil pipe joint; oil leakage from damaged part • Defective monitor • Add oil specified level. * See CHECK BEFORE STARTING. • Replace cartridge. ** See EVERY 500 HOURS SERVICE. • (Check, repair.) • (Replace.) Steam is emitted from top part of radiator (pressure valve).
Water temperature gauge is in red range. Coolant temperature monitor illuminates. • Cooling water level low, water leakage • Dirt or scale accumulated in cooling system • Clogged radiator fin or damaged fin • Defective thermostat • Loose radiator filler cap (high altitude operation) • Defective monitor • Check, add cooling water, repair. *** See WHEN REQUIRED. • Change cooling water, clean inside of cooling system. *** See WHEN REQUIRED. • Clean or repair. *** See WHEN REQUIRED. • (Replace thermostat.) • Tighten cap or replace packing. • (Replace.) Water temperature gauge is in white range on left.
• Defective thermostat • Defective monitor • (Replace thermostat.) • (Replace.) Engine does not start when starting motor is turned. • Lack of fuel • Air in fuel system • Defective supply pump or injector • Starting motor cranks engine too slowly. • Engine preheating pilot lamp does not illuminate. • Defective compression • Defective valve clearance • Add fuel. * See CHECK BEFORE STARTING. • Repair place where air is sucked in. • (Replace pump or nozzle.) • **** See ELECTRICAL SYSTEM • **** See ELECTRICAL SYSTEM • (Check, repair.) • (Adjust valve clearance.) Exhaust gas is white or blue. • Too much oil in oil pan • Lack of fuel • Add oil to specified level. * See CHECK BEFORE STARTING.
• Add fuel * See CHECK BEFORE STARTING. Exhaust gas occasionally turns black. • Clogged air cleaner element • Defective nozzle • Defective compression • Defective turbocharger • Defective injector • Clean or replace. *** See WHEN REQUIRED. • (Replace nozzle.) • (Check, repair.) • (Clean or replace turbocharger.) • (Check, adjust, repair.) Combustion noise occasionally makes breathing sound. • Defective nozzle • (Replace nozzle.) Abnormal noise generated (combustion or mechanical). • Low grade fuel being used • Overheating • Damage inside muffler • Excessive valve clearance • Change to specified fuel. • Refer to “Water temperature gauge is in red range” in this table. • Replace muffler.
• (Adjust valve clearance.) Error code displayed on monitor Contact your Komatsu distributor. Alarm buzzer sounds. Engine suddenly lost power (entered delay mode)