Komatsu — Relationship of Electronic Control System

OPERATION WA500-3LK 2-131 Error Code Option Alarm Buzzer Action by Operator Joystick Control System Electronic Governor System Problem System Condition of Machine Problem system Condition of machine E00 Disconnection, short circuit, or short circuit with ground in joystick FNR signal system Returns to neutral (possible to manual switch) - - No Normal work possible with manual operation - - - - Normal work possible, but there is gearshifting shock - - - - E01+ CALL - - - - Yes Travel under own power possible; move to safe place; call service - - Power supply Not cut when starting switch is turned OFF - - Supply pump drive circuit Deterioration in emission - - Supply pump Deterioration in emission - - Common rail pressure normal (1st stage) Normal operation - - Impossible to control common rail drop in pressure (1st stage) Deterioration in emission; increase in noise - - Disconnection in TWV Drop in output; increase in noise