MAINTENANCE Clean Inside of Cooling System Immediately after stopping the engine, the engine coolant is VERY HOT and the pressure inside the radiator is high. Removing the cap and draining the coolant under this condition could cause burns. Allow the engine to cool down and then turn the cap slowly to release the pressure. Start the engine and flush the system. When standing up or leaving the operator’s seat, set the safety lock lever to the LOCK position. For details of starting the engine, see “Check Before Starting Engine” on page 2-45, “Adjusting Work Equipment” on page 2-91, and “Starting Engine” on page 2-56 in the Operation section of this manual.
When the undercover is removed, there is danger of touching the fan. Never enter the rear of the machine when the engine is running. Stop the machine on level ground when cleaning or changing the coolant. Clean the inside of the cooling system; change the coolant; and replace the corrosion resistor according to the following table. * Permanent-type antifreeze must meet the requirements of ASTM D3306-03. The coolant prevents corrosion as well as freezing. Even in areas where freezing is not an issue, the use of an antifreeze coolant is essential. Use Supercoolant (AF-NAC) at a mixing ratio of at least 30% to prevent corrosion of the cooling system.
Komatsu machines are supplied with Komatsu Supercoolant (AF-NAC). Komatsu Supercoolant (AF-NAC) has excellent anti-corrosion, antifreeze, and cooling properties and can be used continuously for two years or 4,000 hours. As a basic rule, we do not recommend the use of any coolant other than Komatsu genuine Supercoolant (AF-NAC). If you use another coolant, it may cause serious problems such as corrosion of the engine and parts of the cooling system that use light medals, such as aluminum. When using Komatsu Supercoolant (AF-NAC), there is no need to use a corrosion resistor.
To maintain the anti-corrosion properties of Supercoolant (AF-NAC), always keep the density of the Supercoolant between 30% and 68%. It is better to estimate a temperature about 10 ° C (50 ° F) lower than the minimum temperature. The mixing ratio depends on the ambient temperature, but it should always be a minimum of 30% by volume (amount of antifreeze/total amount of coolant in system x 100). The freezing temperature of 100% undiluted Supercoolant is -15 ° C (5 ° F). Do not store undiluted Supercoolant at a temperature below -15 ° C (5 ° F).
3-24 WA500-3LK Antifreeze Coolant Interval for Cleaning Inside Cooling system and Changing Antifreeze Coolant Replacing Corrosion Resistor Komatsu Supercoolant (AF-NAC) Every two years or every 4,000 hours, whichever comes first Every 1,000 hours; when cleaning the interior of the cooling system; when changing coolant Permanent-type antifreeze (All-season type) * Every year (autumn) or every 2,000 hours, whichever comes first