Komatsu — Starting Auto-Greasing

AUTO-GREASING SYSTEM OPTIONS, ATTACHMENTS The auto-greasing system automatically supplies grease to many of the moving parts of the machine. This system consists of an electric pump, valves, and a lubrication controller with microcomputer. The lubrication controller is located inside a box under the step on the left side of the machine. If any abnormality occurs in the lubrication controller, inform your Komatsu distributor of the symptoms and ask for repairs. Method of Operation Immediately after the starting switch is turned ON, all the display lamps on the lubrication controller light up for several seconds. This is a self-check for the lamps and does not indicate any abnormality.

The display portion for starting the calculation of the greasing interval will remain on and flashing after the first initial seconds; all other displays will go out. If the starting switch is turned ON/OFF repeatedly, even if the greasing interval has not been reached, greasing will automatically start (as a function of the supplemental circuit) immediately after the switch is turned ON. After display of the 7-segment LED and greasing LED, as shown in “Lubrication Controller Display” on page 5-8, the above condition will be returned. After the starting switch is turned ON, centralized greasing is carried out in accordance with the set time and frequency limit for greasing.

Remark If the starting switch is turned ON/OFF frequently before the greasing interval is reached, the warning for the remaining time is displayed earlier; this does not indicate an abnormality. Starting Auto-Greasing It is possible to start the system and perform one manual cycle of greasing regardless of the time count. 1. Press the auto-greasing switch (1) on the main monitor or the starting button on the lubrication controller. This cancels the greasing time count. After the electric pump finishes the manual cycle, the timer will restart automatically. Avoid pressing the auto-greasing switch as much as possible. 2.

When the engine starting switch is turned one stage, the auto- greasing system is automatically set to begin actuation and the lamp (4) on the monitor panel lights up. Each time the auto-greasing switch (1) is pressed, the system manually forces grease to the machine. Pilot lamp indications: Lamp illuminated: Normal operation. Lamp flashes at 1-second interval: Grease cartridge empty. Lamp flashes at 0.5-second interval: Improper release of pressure; pump pressurized; pressure detected in system; or a fuse is blown. WA500-3LK 5-7