Komatsu — OTHER TROUBLE

. OPERATION TROUBLES AND ACTIONS Machine Monitoring System (*): For details of handling the emergency pump drive switch and swing holding brake cancel switch, see "SWITCHES (PAGE 3-28)". 3 - 161 Electronic Control System If an error code is displayed on the machin e monitor display, follow the self-diagnostic remedy table below. Monitor display Failure mode Remedy E02 TVC valve system error When emergency pump drive switch is up, normal operations become normal, but carry out inspection immediately. (*) E03 Swing brake system error Turn the swing holding brake release switch is up to release the brake. When applying the swing brake, operate it manually with the swing lock switch.

Depending on the cause of the problem, it may not be possible to release it. In any case, have it inspected immediately.(*) E10 Abnormality in electronic governor system (engine stopped) Carry out inspection immediately. E11 E14 Abnormality in electronic governor system (abnormality in engine protection output) Abnormality in throttle (abnormality in fuel control dial) It is possible to carry out normal working operations, but have inspection carried out immediately. Move machine to a safe posture, and carry out inspection immediately. E15 Abnormality in electronic governor system It is possible to carry out normal driving operations, but have inspection carried out immediately.

E0E Abnormality in network If the engine can be operated, set the machine to a safe posture, then have inspection carried out immediately. If the engine is operated and stalls, turn the emergency pump drive switch is up set the machine to a safe posture, then have inspection carried out immediately. Even if the engine is stopped, have inspection carried out immediately. CALL Operation cannot be continued Move machine to a safe posture, and carry out inspection immediately. If no error code is displayed but work equipment or swing cannot be operated Carry out inspection immediately.