Komatsu — WHEN REQUIRED

. MAINTENANCE MAINTENANCE PROCEDURE CLEAN INSIDE OF COOLING SYSTEM WARNING Stop the machine on level ground when cleaning or changing the coolant. Use a permanent type of antifreeze. If, for some reason, it is impossible to use permanent type antifreeze, use an antifreeze containing ethylene glycol. Super Coolant (AF-ACL) has an anti-corrosion effect as well as an antifreeze effect. The ratio of antifreeze to water depends on the ambient temperature, but to obtain the corrosion resistance effect, a minimum ratio of 30% by volume is necessary. When deciding the ratio of antifreeze to water, check the lowest temperature in the past, and decide from the mixing rate table given below.

It is actually better to estimate a temperature about 10 ° C (18 ° F) lower when deciding the mixing rate. Mixing rate of water and antifreeze 4 - 24 Immediately after the engine i s stopped, the coolant i s at a high temperature and the radiator is under high interna l pressure. If the cap is r emoved t o drain th e coolant in this condition, t here i s a hazard of burns. Wait f or the temperatur e to go down , then turn the cap slowly to release t he pressu re before removin g it. Cleaning is c arried ou t with the engine running. When standing u p or leaving the o perator's seat, set the lock lever t o the LOCK position.

For d etails o f starting the engin e, see"BEFORE STARTING ENGI NE (PAGE 3-75)" and "STARTING ENGINE ( PAGE 3 -94)" in the OPERATION section. ching the fan if the undercover is left removed. e machine when the engine is running. Ther e is danger of tou ching th e fan if the undercover is lef t rem Neve r enter behind th e machin e when th e engine is r unnin Clean t he inside of the cooling system, change the coolant a nd replace the corrosio n resistor according t o the table below.

Kind of coolant Cleaning inside of cooling system and changing coolant Replacing corrosion resistor Permanent type antifreeze (All season type) Every year (autumn) or every 2000 hours, whichever comes first Every 1000 hours and when cleaning the inside of the cooling system and when changing coolant Non permanent type antifreeze containing ethylene glycol (winter, one season type) Every 6 months (spring, autumn) (Drain antifreeze in spring, add antifreeze in autumn) When not using antifreeze Every 6 months or every 1000 hours, whichever come first Min.

atmospheric temperature °C °F - 10 - 15 - 20 - 25 - 30 -35 -40 14 5 - 4 - 13 - 22 -31 -40 Amount of antifreeze liters US gal 25.5 30.5 34.8 39.0 42.5 45.9 49.3 6.8 8.1 9.2 10.3 11.25 12.13 13.03 liters 59.5 54.5 50.2 46.0 42.5 39.1 35.7 US gal 15.7 14.4 13.3 12.2 11.25 10.37 Proportion by volume % 30 36 41 46 50 54 58