hitachi — REMOVE AND INSTALL PUMP DEVICE

UPPERSTRUCTURE / Pump Device REMOVE AND INSTALL PUMP DEVICE CAUTION: Release any pressure in the hydraulic oil tank before doing any work. (Refer to BLEED AIR FROM HYDRAULIC OIL TANK on W1-4-1.) Removal 1. Remove bolts (1) (8 used) and washers (2) (8 used) from pre-cleaner (3). Remove pre-cleaner (3) from cover (4). : 17 mm 2. Remove bolts (6) (4 used) and washers (7) (4 used) from stay (5). Remove stay (5) from cover (8). 1, 2 6, 7 8 : 19 mm 3. Open cover (9). 4. Remove lock pin (12) and washer (11) from stay (10). Remove stay (10) from bracket (13). 5. Remove bolts (14) (6 used) and washers (15) (6 used) from cover (9). Remove cover (9) from support (16).

W1JB-02-04-010 9 10 11 12 13 W1JB-02-04-021 Detail A A 9 14, 15 : 17 mm 16 W1JB-02-04-020 W2-4-1 3 4 5