hitachi — DISASSEMBLE MAIN REGULATOR

UPPERSTRUCTURE / Pump Device Disassemble Main Regulator 1. Remove socket bolts (36, 38) (2 used for each) from casing (37). Remove the regulator from the pump. Remove pin (57) and O-rings (60, 61) from casing (37). 7. Remove socket bolts (69) (4 used) from cover (68). Remove cover (68) from casing (37). : 5 mm 8. Remove O-rings (62, 63, 64, 65) and spring (29) from casing (37). 9. Remove retaining ring (31) from spool (25). Remove spring seat (30), spring (29) and sleeve (26) from spool (25). 10. Remove retaining ring (27) from sleeve (26). 11. Remove pin (1), sleeve (2) and O-ring (3) from casing (37). 12. Remove lock rings (53, 54) from casing (37). IMPORTANT:

As supporting plugs (51, 56) are quite similar, align the matching marks in order not to confuse. 13. Insert bolt (M6, Pitch 1.0 mm) into the center hole of supporting plugs (51, 56). Remove supporting plugs (51, 56) from casing (37). Pin (50) is removed with supporting plug (51) together. 14. Remove pin (50) from supporting plug (51). : 6 mm 2. Remove socket bolts (66) (2 used) from solenoid valve (67). Remove solenoid valve (67) from cover (68). : 4 mm 3. Remove socket bolts (32) (4 used) from cover (33). Remove cover (33), O-rings (34), and (35) (3 used) from casing (37). : 5 mm IMPORTANT:

Do not disassemble lock nuts (42, 46, 47) and adjusting screws (40, 41, 48) as the setting of flow rate changes. When removing cover (44), springs (9, 10) inside may fly out. 4. Remove socket bolts (45) (4 used) from cover (44). Remove the cover (44) assembly and O-ring (43) from casing (37). : 5 mm 5. Remove springs (9, 10) and spring seat (8) from casing (37). 6. Remove stopper (11) and O-ring (12) from the cover (44) assembly. W2-4-41