hitachi — DISASSEMBLE FAN PUMP

UPPERSTRUCTURE / Pump Device 10. Tap and remove support (30) from pump casing (27) by using a plastic hammer. At this time, remove O-rings (28), (26) (5 used) and spring pin (11). 11. Remove swash plate (32) and shoe plate (33) from pump casing (27). 12. Tap and remove drive shaft (5) from support (30) by using a plastic hammer. 13. Install the bolt (M5, Pitch: 0.8 mm) to stoppers (12, 25). Remove stoppers (12, 25) from pump casing (27). 14. Remove backup rings (13, 24) and O-rings (14, 23) from stoppers (12, 25). IMPORTANT: LOCTITE has been applied onto the contacting part between servo piston (22) and tilt pin (19). Do not disassemble them. 15. Heat tilt pin (19) by using a drier.

Secure servo piston (22) by using a pair of pliers in order not to damage. Rotate and remove tilt pin (19). Remove servo piston (22) from pump casing (27). IMPORTANT: Do not remove needle bearing (40) unless necessary. 16. Remove needle bearing (40) from cover (46). 17. Remove retaining ring (8) from drive shaft (5). Remove spacer (6), roller bearing (7) and spacer (6) from drive shaft (5). W2-4-53