UPPERSTRUCTURE / Pump Device Disassemble Fan Regulator 1. Remove socket bolts (18) (6 used) from casing (19). Remove the casing (19) assembly from the pump casing. IMPORTANT: As the pump control changes, do not loosen screw (7) and nut (8). 7. Remove socket bolts (6) (4 used) from cover (5). Remove the cover (5) assembly from casing (19). : 6 mm 2. Remove O-rings (4, 23, 24) and pin (22) from casing (19). 3. Remove socket bolts (13) (2 used) from solenoid valve (12). Remove solenoid valve (12) from valve casing (10). : 5 mm 8. Install the bolt (M4, Pitch 0.7 mm) to stopper (3). Remove stopper (3), spring (2) and spring seat (1) from casing (19). 9. Remove plug (21) from casing (19).
Remove feedback lever (26), pin (27), sleeve (28) and spool (25) from housing (19). : 4 mm 4. Remove socket bolts (9), (34) (4 used) from valve casing (10). Remove valve casing (10) from casing (19). : 6 mm : 5 mm 5. Remove O-rings (14) (2 used), seats (15) (2 used), steel balls (16) (2 used) and stoppers (17) (2 used) from casing (19). 6. Remove O-ring (31), sleeve (30) and pin (29) from casing (19). NOTE: Feedback lever (26) and pin (27) are removed together. NOTE: As for the positions of O-ring (14), steel ball (16) and stopper (17), refer to W2-4-60. W2-4-59