hitachi — ASSEMBLE FAN REGULATOR

UPPERSTRUCTURE / Pump Device Assemble Fan Regulator 1. Install stopper (17), steel ball (16), seat (15) and O-ring (19) to the mounting surface for pump casing in casing (19). IMPORTANT: Check the direction to insert sleeve (28) and spool (25). 2. Install sleeve (28) and spool (25) to casing (19). Install feedback lever (26) to sleeve (28) with pin (27). 3. Install O-ring (10) to plug (21). Align with the pin hole on feedback lever (26) and install plug (21) to casing (19). 7. Install solenoid valve (12) to valve casing (10) with socket bolts (13) (2 used). : 6.9 N m (0.7 kgf m, 5.1 lbf ft) 8. Install valve casing (10) to casing (19) with socket bolts (9) and (34) (4 used). : 4 mm : 5 mm :

12 N m (1.2 kgf m, 8.9 lbf ft) : 6 mm : 36 N m (3.7 kgf m, 26.6 lbf ft) NOTE: After installing plug (21), check if feedback lever (26) moves smoothly. 4. Install spring seat (1), spring (2), stopper (3) and O-ring (4) to the mounting surface for valve casing (10) in casing (19). Install cover (5) to casing (19) with socket bolts (6) (4 used). : 5 mm : 12 N m (1.2 kgf m, 8.9 lbf ft) 5. Install piston (29), sleeve (30) and O-ring (31) to casing (19). 6. Install stopper (17), steel ball (16), seat (15) and O-ring (14) to casing (19). W2-4-63