hitachi — REMOVE AND INSTALL CONTROL VALVE

UPPERSTRUCTURE / Control Valve REMOVE AND INSTALL CONTROL VALVE CAUTION: Release any pressure in the hy- draulic oil tank before doing any work. (Refer to BLEED AIR FROM HYDRAULIC OIL TANK on W1-4-1.) Removal 1. Remove bolts (3) (11 used). Remove covers (2, 4) from main frame (1). 3 2 4 : 19 mm 2. Remove the signal control valve. (Refer to “Re- move and Install Signal Control Valve" on page W2-10-1.) 3. Remove the 4-spool solenoid valve. Refer to “Remove and Install 4-Spool Solenoid Valve" on page W2-9-1. 4. Remove all the hoses and pipes from control valve (5). Attach an identification tag onto the re- moved hoses for assembling. Cap the open ends. 3 1 W1JB-02-05-001 1 :

17 mm, 19 mm, 41 mm : 12 mm W2-5-1 Signal Control Valve 5 4-Spool Solenoid W1JB-02-05-004 Valve Signal Control Valve 4-Spool Solenoid Valve