hitachi — MAINTENANCE STANDARD

UPPERSTRUCTURE / Swing Device MAINTENANCE STANDARD Swing Motor NOTE: If items 1 to 4 are out of allowable limit, replace them. 1. Clearance between plunger outer diameter and rotor bore D-d W107-02-06-138 W107-02-06-139 2. Clearance between plunger and shoe bottom δ W107-02-06-140 3. Shoe thickness Shoe t t W107-02-06-142 W2-6-23 Plung d Plung er Standard Clearance Allowable Limit 0.032 mm (0.001 in) 0.062 mm (0.002 in) D D Rotor δ Plunger Shoe Standard Clearance Allowable Limit 0 mm 0.3 mm (0.012 in) Standard Thickness Allowable Limit 6.0 mm (0.24 in) 5.8 mm (0.23 in)