hitachi — REMOVE AND INSTALL 4-SPOOL SOLENOID VALVE

UPPERSTRUCTURE / Solenoid Valve REMOVE AND INSTALL 4-SPOOL SOLENOID VALVE CAUTION: Release any pressure in the hydraulic oil tank before doing any work. (Refer to BLEED AIR FROM HYDRAULIC OIL TANK on W1-4-1.) Removal 1. Remove bolts (3) (11 used). Remove covers (2, 4) from main frame (1). 3 2 4 : 19 mm 2. Remove all hoses, pipes and connectors (7) (4 used) from 4-spool solenoid valve (5). Attach an identification tag onto the removed hoses for assembling. Cap the open ends. 3 1 1 Signal Control Valve 5 W1JB-02-05-001 : 17, 19 mm 3. Remove bolts (8) (2 used). Remove 4-spool solenoid valve (5) from control valve (6). 6 W1JB-02-05-004 6 : 17 mm 5 7 8 W1JB-02-09-005 W2-9-1