UPPERSTRUCTURE / Shockless Valve Installation 1. Install shockless valve (7) to bracket (6) with bolts (5) (2 used). 5 : 20 N m (2 kgf m, 15 lbf ft) 2. Install the hoses (2 used) to shockless valve (7). : 13 mm 6 : 19 mm 7 : 29.5 N m (3 kgf m, 22 lbf ft) 3. Install cover (2) onto main frame (1) with bolts (3) (8 used) and washers (4) (8 used). W1JB-02-11-001 8 1 2 : 19 mm : 90 N m (9 kgf m, 66 lbf ft) 3, 4 W1JB-02-11-002 W2-11-2