hitachi — REMOVE AND INSTALL FAN VALVE

UPPERSTRUCTURE / Fan Valve Removal of Fan Valve for Radiator 1. Remove split pins (1) (2 used). Remove pins (2) (2 used) and stay (4) from bracket (3). 2. Remove hoses (7) (6 used) from fan valve (5). Cap the open ends. 1, 2 3 4 W1JB-02-13-007 5 7 6 : 36 mm 3. Remove bolts (8) (2 used). Remove fan valve (5) from bracket (6). : 17 mm W1JB-02-12-008 7 8 W2-13-4