UNDERCARRIAGE / Travel Device Disassemble Travel Device CAUTION: Motor (3) weight: 135 kg (300 lb) 2. Put the matching marks on the mating positions of motor (3) and housing (5). Install eyebolts (M12, Pitch 1.75 mm) (2 used) to the diagonal positions in motor (3). Remove bolts (1) (4 used) and spring washers (2) (4 used). Hoist and remove motor (3). Remove O-ring (4) from motor (3). CAUTION: There may be pressure accumulated inside of the travel device. Loosen the air bleed plug and release any remaining pressure completely. Remove the drain plug. Drain off gear oil. As the plug or gear oil gush out, do not loosen the air bleed plug suddenly. Keep away from the plug. : 27 mm 5 CAUTION:
Travel device weight: 1085 kg (2400 lb) 1. Hoist and hold the travel device. Loosen plug (50-B) by two to three turns. Remove drain plug (50-A). Drain off gear oil from the travel device. Place the travel device on the workbench with the motor (3) side facing upward. 1, 2 3 Eyebolt Mounting Positions W16J-03-02-002 CAUTION: Travel reduction gear weight: 960 kg (2120 lb) 3. Attach a nylon sling onto the body of drum (10). Place the travel device on the workbench with the cover (47) side facing upward. W111-03-02-006 W3-2-5 50-B 50-A