Toyota — SWITCH BOX

2-8 Point Operations [POINT 1] Inspection: Inspect each switch in the ON and OFF positions. (CN69) Inspection: Inspect the applied voltage of the LED.Check the applied voltage of the LED at the display connector (CN70).

(CN69 must be connected.) CN70 Measurement terminals ON OFF Tester range NORMAL button 2−8 0 Ω ∞ Ω × 1 EQUAL button 3−8 0 Ω ∞ UP LED EQUAL LED CN70 14 13 12 11 10 9 8 30 29 28 27 26 25 24 23 22 NORMAL LED 13 12 11 10 9 8 29 28 27 26 25 24 23 22 28 23 NORMAL LED CN70 Charging in progress (LED on) Charging stopped (LED off) Tester range NORMAL LED Between 9 and 30 (between Y−B and B−W) 2 V 0 V 10 VDC EQUAL LED Between 10 and 30 (between Y−G and B−W) 2 V 0 V CN70 Upon end of test mode (LED on) Other state (LED off) Tester range UP LED Between 11 and 30 (between Y−W and B−W) 2 V 0 V 10 VDC