Doosan D80S-5 — Doosan D80S-5 User Manual

Maintenance Section First 250 Service Hours or a Month You must read and understand the warnings and instructions contained in the Safety section of this manual, before performing any operation or maintenance procedures. Hydraulic Return Filter – Change 4. Clean the filter housing with a clean, nonflammable solvent. 5. Clean the housing base. 6. Insert a new filter element into the filter housing. 7. Inspect the filter housing seal. Replace if necessary. 8. Apply a small amount of clean oil to the filter element seal and housing seal. 9. Install the filter housing with filter to the housing base. Install bolts and tighten 20 to 30 N•m (15 to 20 lb•ft). 10.

Start the engine and operate the hydraulic controls, and the steering system, through a few cycles to fill the lines. Look for oil leaks. 11. Stop the engine and check the oil level. With all cylinders retracted, maintain the oil level to the FULL mark on the dip stick/filter cap assembly. Hot oil and components can cause personal injury. Do not allow hot oil or components to contact skin. Park the lift truck level with the forks lowered, parking brake engaged, transmission in NEUTRAL and the engine stopped. 1. Remove the floor plate. 2. Remove bolts and filter housing. 3. Remove and discard filter element from filter housing. 159 WARNING